RO supports multiple calculations. Starting with Water Production (initial and final readings).
Enter initial and final water production values for each RO plant to get the produced amount.
| RO Plant | Initial Water Production | Final Water Production | Produced Water |
|---|---|---|---|
| RO Plant 1 | 0 | ||
| RO Plant 2 | 0 |
Enter initial and final distribution values for distribution pumps.
| Pump | Initial Distribution | Final Distribution | Distribution Difference |
|---|---|---|---|
| Pump | 0 |
Previous Day and Today are auto-set from current date. Enter 24-hour start and end times.
| Pump | Previous Day | Today | Start Time (24h) | End Time (24h) | Total Hours |
|---|---|---|---|---|---|
| Pump 1 | 0h 00m (0.00) |
Enter initial and final STELCO CT meter readings.
| Meter | Initial Reading | Final Reading | Difference |
|---|---|---|---|
| STELCO CT Meter | 0 |
Enter initial and final kW readings for RO 1 and RO 2.
| RO | Initial kW | Final kW | kW Difference |
|---|---|---|---|
| RO 1 | 0 | ||
| RO 2 | 0 |
Enter water level (m) for each tank. Volume (CBM) is auto-calculated as level x 112.
| Tank | Water Level (m) | Volume (CBM) |
|---|---|---|
| Tank 1 | 0 | |
| Tank 2 | 0 | |
| RW Tank | 0 |
Previous Day and Today are auto-set from current date. Enter 24-hour start and end times.
| RO Plant | Previous Day | Today | Start Time (24h) | End Time (24h) | Total Hours |
|---|---|---|---|---|---|
| RO Plant 1 | 0h 00m (0.00) | ||||
| RO Plant 2 | 0h 00m (0.00) |
Select a shift, enter genset data, then fill Daily Log.
Cloud sync: connecting...
Enter initial and final units for each genset to calculate unit difference. Use + to add another reading pair if the engine was stopped and restarted.
| Genset | Readings (Initial → Final) | Difference |
|---|---|---|
| Genset 1 |
|
0 |
| Genset 2 |
|
0 |
| Genset 3 |
|
0 |
| Genset 4 |
|
0 |
Enter initial and final STELCO CT meter readings for genset reporting.
| Meter | Initial Reading | Final Reading | Difference |
|---|---|---|---|
| STELCO CT Meter | 0 |
Previous Day and Today are auto-set from current date. Enter 24-hour start and end times. Use + to add another run if the engine was stopped and restarted.
| Genset | Previous Day | Today | Run Times (Start → End) | Total Hours |
|---|---|---|---|---|
| Genset 1 |
|
0h 00m (0.00) | ||
| Genset 2 |
|
0h 00m (0.00) | ||
| Genset 3 |
|
0h 00m (0.00) | ||
| Genset 4 |
|
0h 00m (0.00) |
Enter fuel consumed (litres) for each genset during this shift.
| Genset | Fuel Consumed (litres) |
|---|---|
| Genset 1 | |
| Genset 2 | |
| Genset 3 | |
| Genset 4 |
Use this section for daily consolidated entries: genset running hours, units, and additional notes.
| Genset | 00:00-08:00 | 08:00-16:00 | 16:00-00:00 | Total |
|---|---|---|---|---|
| Genset 1 | 0 | |||
| Genset 2 | 0 | |||
| Genset 3 | 0 | |||
| Genset 4 | 0 | |||
| Shift Total | 0:00 | 0:00 | 0:00 | 0:00 |
| Genset | 00:00-08:00 | 08:00-16:00 | 16:00-00:00 | Total |
|---|---|---|---|---|
| Genset 1 | 0 | |||
| Genset 2 | 0 | |||
| Genset 3 | 0 | |||
| Genset 4 | 0 | |||
| Shift Total | 0 | 0 | 0 | 0 |
| Genset | 00:00-08:00 | 08:00-16:00 | 16:00-00:00 | Total |
|---|---|---|---|---|
| Genset 1 | 0 | |||
| Genset 2 | 0 | |||
| Genset 3 | 0 | |||
| Genset 4 | 0 | |||
| Shift Total | 0 | 0 | 0 | 0 |
Add any extra information (RO summary, pump issues, maintenance work, fuel updates, etc.).
App and companion tools for this PC.
Clear local saved data, browser caches for this app, and reset all form fields on screen. Observer switches are kept. Cloud Firebase data is not deleted.
Ready
Control the companion observer on this PC. OCR reads GEN UNITS, KILOWATT(kW), and COOLER(°C). Prefix routes genset: 1→SET 1, 8→SET 2, 5→SET 3, 2→SET 4.
Observer: not connected — run observer\\run.ps1